Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 126
Filtrar
1.
Lancet ; 403(10436): 1543-1553, 2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38604209

RESUMEN

BACKGROUND: The coronary sinus reducer (CSR) is proposed to reduce angina in patients with stable coronary artery disease by improving myocardial perfusion. We aimed to measure its efficacy, compared with placebo, on myocardial ischaemia reduction and symptom improvement. METHODS: ORBITA-COSMIC was a double-blind, randomised, placebo-controlled trial conducted at six UK hospitals. Patients aged 18 years or older with angina, stable coronary artery disease, ischaemia, and no further options for treatment were eligible. All patients completed a quantitative adenosine-stress perfusion cardiac magnetic resonance scan, symptom and quality-of-life questionnaires, and a treadmill exercise test before entering a 2-week symptom assessment phase, in which patients reported their angina symptoms using a smartphone application (ORBITA-app). Patients were randomly assigned (1:1) to receive either CSR or placebo. Both participants and investigators were masked to study assignment. After the CSR implantation or placebo procedure, patients entered a 6-month blinded follow-up phase in which they reported their daily symptoms in the ORBITA-app. At 6 months, all assessments were repeated. The primary outcome was myocardial blood flow in segments designated ischaemic at enrolment during the adenosine-stress perfusion cardiac magnetic resonance scan. The primary symptom outcome was the number of daily angina episodes. Analysis was done by intention-to-treat and followed Bayesian methodology. The study is registered with ClinicalTrials.gov, NCT04892537, and completed. FINDINGS: Between May 26, 2021, and June 28, 2023, 61 patients were enrolled, of whom 51 (44 [86%] male; seven [14%] female) were randomly assigned to either the CSR group (n=25) or the placebo group (n=26). Of these, 50 patients were included in the intention-to-treat analysis (24 in the CSR group and 26 in the placebo group). 454 (57%) of 800 imaged cardiac segments were ischaemic at enrolment, with a median stress myocardial blood flow of 1·08 mL/min per g (IQR 0·77-1·41). Myocardial blood flow in ischaemic segments did not improve with CSR compared with placebo (difference 0·06 mL/min per g [95% CrI -0·09 to 0·20]; Pr(Benefit)=78·8%). The number of daily angina episodes was reduced with CSR compared with placebo (OR 1·40 [95% CrI 1·08 to 1·83]; Pr(Benefit)=99·4%). There were two CSR embolisation events in the CSR group, and no acute coronary syndrome events or deaths in either group. INTERPRETATION: ORBITA-COSMIC found no evidence that the CSR improved transmural myocardial perfusion, but the CSR did improve angina compared with placebo. These findings provide evidence for the use of CSR as a further antianginal option for patients with stable coronary artery disease. FUNDING: Medical Research Council, Imperial College Healthcare Charity, National Institute for Health and Care Research Imperial Biomedical Research Centre, St Mary's Coronary Flow Trust, British Heart Foundation.


Asunto(s)
Angina Estable , Enfermedad de la Arteria Coronaria , Seno Coronario , Intervención Coronaria Percutánea , Humanos , Masculino , Femenino , Enfermedad de la Arteria Coronaria/terapia , Angina Estable/tratamiento farmacológico , Seno Coronario/diagnóstico por imagen , Teorema de Bayes , Resultado del Tratamiento , Intervención Coronaria Percutánea/efectos adversos , Método Doble Ciego , Isquemia , Adenosina
2.
Cardiovasc. revasc. med ; 59: 60-66, fev.2024. ilus, tab
Artículo en Inglés | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1527062

RESUMEN

BACKGROUND: Landmark trials showed that invasive pressure measurement (Fractional Flow Reserve, FFR) was a better guide to coronary stenting than visual assessment. However, present-day interventionists have benefited from extensive research and personal experience of mapping anatomy to hemodynamics. AIMS: To determine if visual assessment of the angiogram performs as well as invasive measurement of coronary physiology. METHODS: 25 interventional cardiologists independently visually assessed the single vessel coronary disease of 200 randomized participants in The Objective Randomized Blinded Investigation with optimal medical Therapy of Angioplasty in stable angina trial (ORBITA). They gave a visual prediction of the FFR and Instantaneous Wave-free Ratio (iFR), denoted vFFR and viFR respectively. Each judged each lesion on 2 occasions, so that every lesion had 50 vFFR, and 50 viFR assessments. The group consensus visual estimates (vFFR-group and viFR-group) and individual cardiologists' visual estimates (vFFR-individual and viFR-individual) were tested alongside invasively measured FFR and iFR for their ability to predict the placebo-controlled reduction in stress echo ischemia with stenting. RESULTS: Placebo-controlled ischemia improvement with stenting was predicted by vFFR-group (p < 0.0001) and viFR-group (p < 0.0001), vFFR-individual (p < 0.0001) and viFR-individual (p < 0.0001). There were no significant differences between the predictive performance of the group visual estimates and their invasive counterparts: p = 0.53 for vFFR vs FFR and p = 0.56 for viFR vs iFR. CONCLUSION: Visual assessment of the angiogram by contemporary experts, provides significant additional information on the amount of ischaemia which can be relieved by placebo-controlled stenting in single vessel coronary artery disease.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Índice de Severidad de la Enfermedad , Estenosis Coronaria
3.
EuroIntervention ; 20(3): e216-e223, 2024 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-38214677

RESUMEN

The coronary sinus Reducer (CSR) is an hourglass-shaped device which creates an artificial stenosis in the coronary sinus. Whilst placebo-controlled data show an improvement in angina, these results are unreplicated and are the subject of further confirmatory research. The mechanism of action of this unintuitive therapy is unknown. The Coronary Sinus Reducer Objective Impact on Symptoms, MRI Ischaemia, and Microvascular Resistance (ORBITA-COSMIC) trial is a randomised, placebo-controlled, double-blind trial investigating the efficacy of the CSR. Patients with (i) established epicardial coronary artery disease, (ii) angina on maximally tolerated antianginal medication, (iii) evidence of myocardial ischaemia and (iv) no further options for percutaneous coronary intervention or coronary artery bypass grafting will be enrolled. Upon enrolment, angina and quality-of-life questionnaires, treadmill exercise testing and quantitative stress perfusion cardiac magnetic resonance (CMR) imaging will be performed. Participants will record their symptoms daily on a smartphone application throughout the trial. After a 2-week symptom assessment phase, participants will be randomised in the cardiac catheterisation laboratory to CSR or a placebo procedure. After 6 months of blinded follow-up, all prerandomisation tests will be repeated. A prespecified subgroup will undergo invasive coronary physiology assessment at prerandomisation and follow-up. The primary outcome is stress myocardial blood flow on CMR. Secondary outcomes include angina frequency, quality of life and treadmill exercise time. (ClinicalTrials.gov: NCT04892537).


Asunto(s)
Angina Estable , Enfermedad de la Arteria Coronaria , Seno Coronario , Intervención Coronaria Percutánea , Humanos , Angina Estable/diagnóstico , Calidad de Vida , Seno Coronario/cirugía , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/terapia
4.
Cardiovasc Revasc Med ; 59: 60-66, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37612169

RESUMEN

BACKGROUND: Landmark trials showed that invasive pressure measurement (Fractional Flow Reserve, FFR) was a better guide to coronary stenting than visual assessment. However, present-day interventionists have benefited from extensive research and personal experience of mapping anatomy to hemodynamics. AIMS: To determine if visual assessment of the angiogram performs as well as invasive measurement of coronary physiology. METHODS: 25 interventional cardiologists independently visually assessed the single vessel coronary disease of 200 randomized participants in The Objective Randomized Blinded Investigation with optimal medical Therapy of Angioplasty in stable angina trial (ORBITA). They gave a visual prediction of the FFR and Instantaneous Wave-free Ratio (iFR), denoted vFFR and viFR respectively. Each judged each lesion on 2 occasions, so that every lesion had 50 vFFR, and 50 viFR assessments. The group consensus visual estimates (vFFR-group and viFR-group) and individual cardiologists' visual estimates (vFFR-individual and viFR-individual) were tested alongside invasively measured FFR and iFR for their ability to predict the placebo-controlled reduction in stress echo ischemia with stenting. RESULTS: Placebo-controlled ischemia improvement with stenting was predicted by vFFR-group (p < 0.0001) and viFR-group (p < 0.0001), vFFR-individual (p < 0.0001) and viFR-individual (p < 0.0001). There were no significant differences between the predictive performance of the group visual estimates and their invasive counterparts: p = 0.53 for vFFR vs FFR and p = 0.56 for viFR vs iFR. CONCLUSION: Visual assessment of the angiogram by contemporary experts, provides significant additional information on the amount of ischaemia which can be relieved by placebo-controlled stenting in single vessel coronary artery disease.


Asunto(s)
Cardiólogos , Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Humanos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Isquemia , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad
5.
N Engl J Med ; 389(25): 2319-2330, 2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-38015442

RESUMEN

BACKGROUND: Percutaneous coronary intervention (PCI) is frequently performed to reduce the symptoms of stable angina. Whether PCI relieves angina more than a placebo procedure in patients who are not receiving antianginal medication remains unknown. METHODS: We conducted a double-blind, randomized, placebo-controlled trial of PCI in patients with stable angina. Patients stopped all antianginal medications and underwent a 2-week symptom assessment phase before randomization. Patients were then randomly assigned in a 1:1 ratio to undergo PCI or a placebo procedure and were followed for 12 weeks. The primary end point was the angina symptom score, which was calculated daily on the basis of the number of angina episodes that occurred on a given day, the number of antianginal medications prescribed on that day, and clinical events, including the occurrence of unblinding owing to unacceptable angina or acute coronary syndrome or death. Scores range from 0 to 79, with higher scores indicating worse health status with respect to angina. RESULTS: A total of 301 patients underwent randomization: 151 to the PCI group and 150 to the placebo group. The mean (±SD) age was 64±9 years, and 79% were men. Ischemia was present in one cardiac territory in 242 patients (80%), in two territories in 52 patients (17%), and in three territories in 7 patients (2%). In the target vessels, the median fractional flow reserve was 0.63 (interquartile range, 0.49 to 0.75), and the median instantaneous wave-free ratio was 0.78 (interquartile range, 0.55 to 0.87). At the 12-week follow-up, the mean angina symptom score was 2.9 in the PCI group and 5.6 in the placebo group (odds ratio, 2.21; 95% confidence interval, 1.41 to 3.47; P<0.001). One patient in the placebo group had unacceptable angina leading to unblinding. Acute coronary syndromes occurred in 4 patients in the PCI group and in 6 patients in the placebo group. CONCLUSIONS: Among patients with stable angina who were receiving little or no antianginal medication and had objective evidence of ischemia, PCI resulted in a lower angina symptom score than a placebo procedure, indicating a better health status with respect to angina. (Funded by the National Institute for Health and Care Research Imperial Biomedical Research Centre and others; ORBITA-2 ClinicalTrials.gov number, NCT03742050.).


Asunto(s)
Angina Estable , Intervención Coronaria Percutánea , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Síndrome Coronario Agudo , Angina Estable/tratamiento farmacológico , Angina Estable/cirugía , Fármacos Cardiovasculares/uso terapéutico , Reserva del Flujo Fraccional Miocárdico , Estado de Salud , Intervención Coronaria Percutánea/métodos , Resultado del Tratamiento , Método Doble Ciego , Isquemia Miocárdica
6.
Eur Heart J Digit Health ; 4(4): 291-301, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37538145

RESUMEN

Aims: Coronary flow reserve (CFR) assessment has proven clinical utility, but Doppler-based methods are sensitive to noise and operator bias, limiting their clinical applicability. The objective of the study is to expand the adoption of invasive Doppler CFR, through the development of artificial intelligence (AI) algorithms to automatically quantify coronary Doppler quality and track flow velocity. Methods and results: A neural network was trained on images extracted from coronary Doppler flow recordings to score signal quality and derive values for coronary flow velocity and CFR. The outputs were independently validated against expert consensus. Artificial intelligence successfully quantified Doppler signal quality, with high agreement with expert consensus (Spearman's rho: 0.94), and within individual experts. Artificial intelligence automatically tracked flow velocity with superior numerical agreement against experts, when compared with the current console algorithm [AI flow vs. expert flow bias -1.68 cm/s, 95% confidence interval (CI) -2.13 to -1.23 cm/s, P < 0.001 with limits of agreement (LOA) -4.03 to 0.68 cm/s; console flow vs. expert flow bias -2.63 cm/s, 95% CI -3.74 to -1.52, P < 0.001, 95% LOA -8.45 to -3.19 cm/s]. Artificial intelligence yielded more precise CFR values [median absolute difference (MAD) against expert CFR: 4.0% for AI and 7.4% for console]. Artificial intelligence tracked lower-quality Doppler signals with lower variability (MAD against expert CFR 8.3% for AI and 16.7% for console). Conclusion: An AI-based system, trained by experts and independently validated, could assign a quality score to Doppler traces and derive coronary flow velocity and CFR. By making Doppler CFR more automated, precise, and operator-independent, AI could expand the clinical applicability of coronary microvascular assessment.

7.
Neth Heart J ; 31(11): 434-443, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37594612

RESUMEN

BACKGROUND: The pressure-derived parameters fractional flow reserve (FFR) and the emerging instantaneous wave-free ratio (iFR) are the most widely applied invasive coronary physiology indices to guide revascularisation. However, approximately 15-20% of intermediate stenoses show discordant FFR and iFR, and therapeutical consensus is lacking. AIMS: We sought to associate hyperaemic stenosis resistance index, coronary flow reserve (CFR) and coronary flow capacity (CFC) to FFR/iFR discordance. METHODS: We assessed pressure and flow measurements of 647 intermediate lesions (593 patients) of two multi-centre international studies. RESULTS: FFR and iFR were discordant in 15% of all lesions (97 out of 647). FFR+/iFR- lesions had similar hyperaemic average peak velocity (hAPV), CFR and CFC as FFR-/iFR- lesions, whereas FFR-/iFR+ lesions had similar hAPV, CFR and CFC as FFR+/iFR+ lesions (p > 0.05 for all). FFR+/iFR- lesions were associated with lower baseline stenosis resistance, but not hyperaemic stenosis resistance, compared with FFR-/iFR+ lesions (p < 0.001). CONCLUSIONS: Discordance with FFR+/iFR- is characterised by maximal flow values, CFR, and CFC patterns similar to FFR-/iFR- concordance that justifies conservative therapy. Discordance with FFR-/iFR+ on the other hand, is characterised by low flow values, CFR, and CFC patterns similar to iFR+/FFR+ concordance that may benefit from percutaneous coronary intervention.

8.
J Thromb Haemost ; 21(8): 2213-2222, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37230416

RESUMEN

BACKGROUND: Patients hospitalized with COVID-19 suffer thrombotic complications. Risk factors for poor outcomes are shared with coronary artery disease. OBJECTIVES: To investigate the efficacy of an acute coronary syndrome regimen in patients hospitalized with COVID-19 and coronary disease risk factors. METHODS: A randomized controlled, open-label trial across acute hospitals (United Kingdom and Brazil) added aspirin, clopidogrel, low-dose rivaroxaban, atorvastatin, and omeprazole to standard care for 28 days. Primary efficacy and safety outcomes were 30-day mortality and bleeding. The key secondary outcome was a daily clinical status (at home, in hospital, on intensive therapy unit admission, or death). RESULTS: Three hundred twenty patients from 9 centers were randomized. The trial terminated early due to low recruitment. At 30 days, there was no significant difference in mortality (intervention vs control, 11.5% vs 15%; unadjusted odds ratio [OR], 0.73; 95% CI, 0.38-1.41; p = .355). Significant bleeds were infrequent and were not significantly different between the arms (intervention vs control, 1.9% vs 1.9%; p > .999). Using a Bayesian Markov longitudinal ordinal model, it was 93% probable that intervention arm participants were more likely to transition to a better clinical state each day (OR, 1.46; 95% credible interval [CrI], 0.88-2.37; Pr [beta > 0], 93%; adjusted OR, 1.50; 95% CrI, 0.91-2.45; Pr [beta > 0], 95%) and median time to discharge to home was 2 days shorter (95% CrI, -4 to 0; 2% probability that it was worse). CONCLUSION: Acute coronary syndrome treatment regimen was associated with a reduction in the length of hospital stay without an excess in major bleeding. A larger trial is needed to evaluate mortality.


Asunto(s)
Síndrome Coronario Agudo , COVID-19 , Humanos , SARS-CoV-2 , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/tratamiento farmacológico , Teorema de Bayes , Aspirina/uso terapéutico , Hemorragia/inducido químicamente , Hemorragia/tratamiento farmacológico , Resultado del Tratamiento
9.
J. thromb. haemost ; 21: 2213-2222, Apr. 2023. graf, ilus, tab
Artículo en Inglés | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1435649

RESUMEN

BACKGROUND: patients hospitalised with covid-19 suffer thrombotic complications. risk factors for poor outcomes are shared with coronary artery disease. Objectives: to investigate efficacy of an acute coronary syndrome regimen in patients hospitalised with covid-19 and coronary disease risk factors. PATIENTS/METHODS: a randomised controlled open-label trial across acute hospitals (uk and brazil) added aspirin, clopidogrel, low-dose rivaroxaban, atorvastatin, and omeprazole to standard care for 28-days. primary efficacy and safety outcomes were 30-day mortality and bleeding. the key secondary outcome was a daily clinical status (at home, in hospital, on intensive therapy unit admission, death). RESULTS: 320 patients from 9 centres were randomised. the trial terminated early due to low recruitment. at 30 days there was no significant difference in mortality (intervention: 11.5% vs control: 15%, unadjusted or 0.73, 95%ci 0.38 to 1.41, p=0.355). significant bleeds were infrequent and not significantly different between the arms (intervention: 1.9% vs control 1.9%, p>0.999). using a bayesian markov longitudinal ordinal model, it was 93% probable that intervention arm participants were more likely to transition to a better clinical state each day (or 1.46, 95% cri 0.88 to 95 2.37, pr(beta>0) =93%; adjusted or 1.50, 95% cri 0.91 to 2.45, pr(beta>0) =95%) and median time to discharge home was two days shorter (95% cri -4 to 0, 2% probability that it was worse). CONCLUSIONS: acute coronary syndrome treatment regimen was associated with a 99 reduction in the length of hospital stay without an excess in major bleeding. a larger trial is needed to evaluate mortality.


Asunto(s)
Síndrome Coronario Agudo , COVID-19
10.
J Soc Cardiovasc Angiogr Interv ; 1(4): 100349, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35992189

RESUMEN

Background: Transcatheter aortic valve replacement (TAVR) is the treatment of choice for patients with severe aortic stenosis who are at a moderate or higher surgical risk. Stroke is a recognised and serious complication of TAVR, and it is important to identify patients at higher stroke risk. This study aims to discover if aortic valve calcium score calculated from pre-TAVR computed tomography is associated with acute stroke in TAVR patients. Methods: We conducted a retrospective, observational cohort study of 433 consecutive patients undergoing TAVR between January 2017 and December 2019 at the Hammersmith Hospital. Results: This cohort had a median age of 83 years (interquartile range, 78-87), and 52.7% were male. Fifty-two patients (12.0%) had a history of previous stroke or transient ischemic attack. Median aortic valve calcium score was 2145 (interquartile range, 1427-3247) Agatston units. Twenty-two patients had a stroke up to the time of discharge (5.1%). In a logistic regression model, aortic valve calcium score was significantly associated with acute stroke (odds ratio [OR], 1.26; 95% confidence interval [CI], 1.01-1.53; P = .02). Acute stroke was also significantly associated with peripheral arterial disease (OR, 4.32; 95% CI, 1.65-10.65; P = .0018) and a longer procedure time (OR, 1.01; 95% CI, 1.00-1.02; P = .0006). Conclusions: Aortic valve calcium score from pre-TAVR computed tomography is an independent risk factor for acute stroke in the TAVR population. This is an additional clinical value of the pre-TAVR aortic valve calcium score and should be considered when discussing periprocedural stroke risk.

11.
J. Transcatheter Interv ; 30(supl.1): 62-62, jul.,2022. graf.
Artículo en Portugués | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1381470

RESUMEN

INTRODUÇÃO: Imagem intravascular é de grande valia na avaliação de estenoses ambíguas e para guiar procedimentos de intervenção coronária percutânea (ICP) no tronco da coronária esquerda (TCE). A necessidade de injeção de contraste para remoção transitória do sangue intraluminal e o grande calibre deste segmento vascular são considerados os principais impedimentos para a utilização da tomografia de coerência óptica (OCT) no TCE. OBJETIVOS: Documentar a factibilidade do uso da OCT na avaliação de lesões no TCE, incluindo a visualização de seu óstio. MÉTODOS: Estudo prospectivo, unicêntrico, de braço único, que avaliou procedimentos consecutivos no TCE no período de Agosto a Dezembro de 2020. O desfecho primário é a qualidade das imagens obtidas, definidas como visualização clara da parede vascular sem contaminação por sangue em ≥ 80% da circunferência do vaso. RESULTADOS: Dezoito pacientes foram incluídos, com um total de 29 corridas de OCT. Destas, 20 (68,9%) foram adquiridas pré-ICP e 9 (31,1%) pós-ICP. A média das idades foi 60,1±12,3 anos, 12 (66,7%) eram homens e 5 (27,8%) diabéticos. Síndrome coronária aguda foi a apresentação de 11 (61,1%) pacientes. A via radial foi utilizada em 13 (72,2%). As lesões do TCE localizavam-se no segmento distal em 9 (50%), corpo 4 (22.2%) e 5 (27,8%) possuíam doença difusa ou predominantemente ostial. Foram utilizados cateteres-guia Judkins Left em 10 (55,6%) e Extra Back-up em 8 (44,4%). Injeção manual de contraste foi realizada em todos os casos. Um total de 8,97±1,52 mL de contraste foi utilizado, sem diferença significativa (p=0,378) entre as imagens pré-ICP (9,15±1,66 mL) e pós-ICP (8,60±1,17 mL) O diâmetro luminal do TCE mediu 4,54±0,72mm (3,21 a 6,08mm) nas imagens pré-ICP e 4,65±0,51mm (3,91 a 5,23mm) nas imagens pós-ICP. O óstio do TCE e sua abertura para a aorta foi visualizado em todos os casos. A distância do cateter-guia até o óstio do TCE mediu 0,81±0,71mm (0,2 a 2,9mm). 1.971 imagens transversais consecutivas de OCT foram analisadas nos segmentos de TCE. Destas, 5,4% foram classificadas como baixa qualidade (≥20% da circunferência vascular ocultada por sangue), e distribuídas mais frequentemente próximas ao cateter-guia (figura). CONCLUSÕES: Utilização da OCT no TCE é possível, com administração de pouco volume de contraste e obtenção de imagens de boa qualidade, incluindo a visualização do óstio do TCE. Sua aplicação em maior escala, e reprodutibilidade por outros operadores necessita ser avaliada.


Asunto(s)
Tomografía de Coherencia Óptica , Intervención Coronaria Percutánea , Enfermedad de la Arteria Coronaria
12.
Eur Heart J ; 43(33): 3132-3145, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35639660

RESUMEN

AIMS: Oxygen-pulse morphology and gas exchange analysis measured during cardiopulmonary exercise testing (CPET) has been associated with myocardial ischaemia. The aim of this analysis was to examine the relationship between CPET parameters, myocardial ischaemia and anginal symptoms in patients with chronic coronary syndrome and to determine the ability of these parameters to predict the placebo-controlled response to percutaneous coronary intervention (PCI). METHODS AND RESULTS: Patients with severe single-vessel coronary artery disease (CAD) were randomized 1:1 to PCI or placebo in the ORBITA trial. Subjects underwent pre-randomization treadmill CPET, dobutamine stress echocardiography (DSE) and symptom assessment. These assessments were repeated at the end of a 6-week blinded follow-up period.A total of 195 patients with CPET data were randomized (102 PCI, 93 placebo). Patients in whom an oxygen-pulse plateau was observed during CPET had higher (more ischaemic) DSE score [+0.82 segments; 95% confidence interval (CI): 0.40 to 1.25, P = 0.0068] and lower fractional flow reserve (-0.07; 95% CI: -0.12 to -0.02, P = 0.011) compared with those without. At lower (more abnormal) oxygen-pulse slopes, there was a larger improvement of the placebo-controlled effect of PCI on DSE score [oxygen-pulse plateau presence (Pinteraction = 0.026) and oxygen-pulse gradient (Pinteraction = 0.023)] and Seattle angina physical-limitation score [oxygen-pulse plateau presence (Pinteraction = 0.037)]. Impaired peak VO2, VE/VCO2 slope, peak oxygen-pulse, and oxygen uptake efficacy slope was significantly associated with higher symptom burden but did not relate to severity of ischaemia or predict response to PCI. CONCLUSION: Although selected CPET parameters relate to severity of angina symptoms and quality of life, only an oxygen-pulse plateau detects the severity of myocardial ischaemia and predicts the placebo-controlled efficacy of PCI in patients with single-vessel CAD.


Asunto(s)
Angina Estable , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Angina Estable/diagnóstico , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/terapia , Prueba de Esfuerzo/métodos , Humanos , Oxígeno , Consumo de Oxígeno/fisiología , Calidad de Vida
14.
Heart ; 109(2): 88-95, 2022 12 22.
Artículo en Inglés | MEDLINE | ID: mdl-35318254

RESUMEN

Nearly half of all patients with angina have non-obstructive coronary artery disease (ANOCA); this is an umbrella term comprising heterogeneous vascular disorders, each with disparate pathophysiology and prognosis. Approximately two-thirds of patients with ANOCA have coronary microvascular disease (CMD). CMD can be secondary to architectural changes within the microcirculation or secondary to vasomotor dysfunction. An inability of the coronary vasculature to augment blood flow in response to heightened myocardial demand is defined as an impaired coronary flow reserve (CFR), which can be measured non-invasively, using imaging, or invasively during cardiac catheterisation. Impaired CFR is associated with myocardial ischaemia and adverse cardiovascular outcomes.The CMD workstream is part of the cardiovascular partnership between the British Heart Foundation and The National Institute for Health Research in the UK and comprises specialist cardiac centres with expertise in coronary physiology assessment. This document outlines the two main modalities (thermodilution and Doppler techniques) for estimation of coronary flow, vasomotor testing using acetylcholine, and outlines a standard operating procedure that could be considered for adoption by national networks. Accurate and timely disease characterisation of patients with ANOCA will enable clinicians to tailor therapy according to their patients' coronary physiology. This has been shown to improve patients' quality of life and may lead to improved cardiovascular outcomes in the long term.


Asunto(s)
Enfermedad de la Arteria Coronaria , Angina Microvascular , Isquemia Miocárdica , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/terapia , Calidad de Vida , Consenso , Microcirculación/fisiología , Vasos Coronarios/diagnóstico por imagen , Circulación Coronaria/fisiología , Angiografía Coronaria
15.
EuroIntervention ; 17(18): 1490-1497, 2022 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-35156616

RESUMEN

Percutaneous coronary intervention (PCI) is frequently performed for stable angina. However, the first blinded trial, ORBITA, did not show a placebo-controlled increment in exercise time in patients with single-vessel disease, at 6 weeks, on maximal antianginal therapy. ORBITA-2 will assess the placebo-controlled efficacy of PCI on angina frequency in patients with single- or multivessel disease, at 12 weeks, on no antianginal therapy. ORBITA-2 is a double-blind placebo-controlled trial randomising participants with (i) angina at presentation, (ii) documented angina during the 2-week pre-randomisation symptom assessment phase, (iii) objective evidence of ischaemia, (iv) single- or multivessel disease, and (v) clinical eligibility for PCI. At enrolment, antianginals will be stopped, and angina questionnaires completed. Participants will record their symptoms on a smartphone application daily throughout the trial and will undergo exercise treadmill testing and stress echocardiography at pre-randomisation. They will then undergo coronary angiography with unblinded invasive physiology assessment. Eligible participants will then be sedated to a deep level of conscious sedation and randomised 1:1 between PCI and placebo. After the 12-week blinded follow-up period, they will return for questionnaires, exercise testing and stress echocardiography assessment. If angina becomes intolerable, antianginals will be introduced using a prespecified medication protocol. The primary outcome is an angina symptom score using an ordinal clinical outcome scale for angina. Secondary outcomes include exercise treadmill time, angina frequency, angina severity and quality of life. Trial registration: ClinicalTrials.gov: NCT03742050.


Asunto(s)
Angina Estable , Fármacos Cardiovasculares , Intervención Coronaria Percutánea , Angina Estable/tratamiento farmacológico , Angina Estable/cirugía , Fármacos Cardiovasculares/uso terapéutico , Angiografía Coronaria , Método Doble Ciego , Humanos , Intervención Coronaria Percutánea/métodos , Calidad de Vida , Resultado del Tratamiento
16.
JTCVS Open ; 12: 158-176, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36590739

RESUMEN

Objectives: Coronary artery bypass grafting (CABG) is performed using anatomic guidance. Data connecting the physiologic significance of the coronary vessel stenosis to the acute physiologic response to grafting are lacking. The Collaborative Pilot Study to Determine the Correlation Between Intraoperative Observations Using Spy Near-Infrared Imaging and Cardiac Catheterization Laboratory Physiological Assessment of Lesion Severity study is the first to compare preintervention coronary physiology with the acute regional myocardial perfusion change (RMP-QC) at CABG in a per-graft analysis. Methods: Non-emergent patients undergoing diagnostic catheterization suitable for multivessel CABG were enrolled. Synergy between Percutaneous Coronary Intervention with Taxus score, fractional flow reserve (FFR), instantaneous wave free ratio (iFR), and quantitative coronary angiography was documented in 75 epicardial coronary arteries, with 62 angiographically intermediate and 13 severe stenoses. At CABG, near-infrared fluorescence analysis quantified the relative change (post- vs pregrafting, termed RMP-QC) in the grafted vessel's perfusion territory. Scatter plots were constructed for RMP-QC versus quantitative coronary angiography and RMP-QC versus FFR/iFR. Exact quadrant randomization test for randomness was used. Results: There was no relationship between RMP-QC and quantitative coronary angiography percent diameter stenosis, whether all study vessels were included (P = .949) or vessels with core-lab quantitative coronary angiography only (P = .922). A significant nonrandom association between RMP-QC and FFR (P = .025), as well as between RMP-QC and iFR (P = .008), was documented. These associations remained when excluding vessels with assigned FFR and iFR values (P = .0092 and P = .0006 for FFR and iFR, respectively). Conclusions: The Collaborative Pilot Study to Determine the Correlation Between Intraoperative Observations Using Spy Near-Infrared Imaging and Cardiac Catheterization Laboratory Physiological Assessment of Lesion Severity study demonstrates there is no association between angiographic coronary stenosis severity and the acute perfusion change after grafting; there is an association between functional stenosis severity and absolute increase in regional myocardial perfusion after CABG.

17.
EuroIntervention ; 17(15): 1260-1270, 2022 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-34338643

RESUMEN

BACKGROUND: Coronary blood flow in humans is known to be predominantly diastolic. Small studies in animals and humans suggest that this is less pronounced or even reversed in the right coronary artery (RCA). AIMS: This study aimed to characterise the phasic patterns of coronary flow in the left versus right coronary arteries of patients undergoing invasive physiological assessment. METHODS: We analysed data from the Iberian-Dutch-English Collaborators (IDEAL) study. A total of 482 simultaneous pressure and flow measurements from 301 patients were included in our analysis. RESULTS: On average, coronary flow was higher in diastole both at rest and during hyperaemia in both the RCA and LCA (mean diastolic-to-systolic velocity ratio [DSVR] was, respectively, 1.85±0.70, 1.76±0.58, 1.53±0.34 and 1.58±0.43 for LCArest, LCAhyp, RCArest and RCAhyp, p<0.001 for between-vessel comparisons). Although the type of RCA dominance affected the DSVR magnitude (RCAdom=1.55±0.35, RCAco-dom=1.40±0.27, RCAnon-dom=1.35; standard deviation not reported as n=3), systolic flow was very rarely predominant (DSVR was greater than or equal to 1.00 in 472/482 cases [97.9%] overall), with equal prevalence in the LCA. Stenosis severity or microvascular dysfunction had a negligible impact on DSVR in both the RCA and LCA (DSVR x hyperaemic stenosis resistance R2 =0.018, p=0.03 and DSVR x coronary flow reserve R2 <0.001, p=0.98). CONCLUSIONS: In patients with coronary artery disease undergoing physiological assessment, diastolic flow predominance is seen in both left and right coronary arteries. Clinical interpretation of coronary physiological data should therefore not differ between the left and the right coronary systems.


Asunto(s)
Vasos Coronarios , Hiperemia , Velocidad del Flujo Sanguíneo/fisiología , Constricción Patológica , Circulación Coronaria/fisiología , Vasos Coronarios/diagnóstico por imagen , Diástole , Humanos
18.
Eur Heart J ; 43(16): 1582-1593, 2022 04 19.
Artículo en Inglés | MEDLINE | ID: mdl-34849697

RESUMEN

AIMS: This meta-analysis aims to quantify the association of reduced coronary flow with all-cause mortality and major adverse cardiovascular events (MACE) across a broad range of patient groups and pathologies. METHODS AND RESULTS: We systematically identified all studies between 1 January 2000 and 1 August 2020, where coronary flow was measured and clinical outcomes were reported. The endpoints were all-cause mortality and MACE. Estimates of effect were calculated from published hazard ratios (HRs) using a random-effects model. Seventy-nine studies with a total of 59 740 subjects were included. Abnormal coronary flow reserve (CFR) was associated with a higher incidence of all-cause mortality [HR: 3.78, 95% confidence interval (CI): 2.39-5.97] and a higher incidence of MACE (HR 3.42, 95% CI: 2.92-3.99). Each 0.1 unit reduction in CFR was associated with a proportional increase in mortality (per 0.1 CFR unit HR: 1.16, 95% CI: 1.04-1.29) and MACE (per 0.1 CFR unit HR: 1.08, 95% CI: 1.04-1.11). In patients with isolated coronary microvascular dysfunction, an abnormal CFR was associated with a higher incidence of mortality (HR: 5.44, 95% CI: 3.78-7.83) and MACE (HR: 3.56, 95% CI: 2.14-5.90). Abnormal CFR was also associated with a higher incidence of MACE in patients with acute coronary syndromes (HR: 3.76, 95% CI: 2.35-6.00), heart failure (HR: 6.38, 95% CI: 1.95-20.90), heart transplant (HR: 3.32, 95% CI: 2.34-4.71), and diabetes mellitus (HR: 7.47, 95% CI: 3.37-16.55). CONCLUSION: Reduced coronary flow is strongly associated with increased risk of all-cause mortality and MACE across a wide range of pathological processes. This finding supports recent recommendations that coronary flow should be measured more routinely in clinical practice, to target aggressive vascular risk modification for individuals at higher risk.


Asunto(s)
Síndrome Coronario Agudo , Sistema Cardiovascular , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Isquemia Miocárdica , Humanos , Pronóstico , Modelos de Riesgos Proporcionales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...